“RD to use” on the Precision charts offers ARD%, CV%, HARD%, MPRD% (the default) and RDHYSLOP.

How QC Analytical Results uses these statistics

“RD to use” on the Precision charts offers ARD%, CV%, HARD%, MPRD% (the default) and RDHYSLOP. In every formula a is Sample 1 and b is Sample 2, the two results of the pair. Neither is the original: the two are a pair, and a difference between them can come from the geology as well as from sampling or the laboratory.

MPRD% and RDHYSLOP keep their sign, so the charts can show a bias between Sample 1 and Sample 2; ARD%, CV% and HARD% are absolute.

The interpretation bands below are general guides. QC Analytical Results’ RD charts draw control lines at ±2 and ±3 standard deviations of the pairs shown (or their robust MAD equivalents), except RD Box and Whiskers, and the Overview judges each check stage against its own limit on the absolute MPRD% (standard limits ±30% for field, ±20% for coarse and ±10% for pulp duplicates).

Only pairs whose mean is at least the threshold (the “Threshold factor” × the lower detection limit) are used, since at very low concentrations small absolute differences give large relative differences.

The formulas

Statistic Formula a = 2.50, b = 2.40
ARD% |a − b| / a × 100 4.00
CV% |a − b| / (√2 × (a + b) / 2) × 100 2.89
HARD% |a − b| / (a + b) × 100 2.04
MPRD% (a − b) / ((a + b) / 2) × 100 +4.08
RDHYSLOP (a − b) / (√2 × (a + b) / 2) × 100 +2.89

The different statistics produce different percentage values from the same pair. All of them measure agreement between the two results of a pair. They differ in what they divide the difference by. ARD% divides by Sample 1, HARD% by the sum, and MPRD% by the pair mean. CV% and RDHYSLOP divide by the pair mean and by √2.

Absolute Relative Difference (ARD%)

ARD% is one of the most common statistics used to evaluate agreement between duplicate measurements. It expresses the absolute difference between two results as a percentage of Sample 1 (a), so it is the one formula that treats the two results differently:

ARD% = |2.50 − 2.40| / 2.50 × 100 = 0.10 / 2.50 × 100 = 4.0

A lower ARD% indicates better agreement and therefore better analytical precision. It is widely applied to laboratory duplicates, field duplicates, check assays, sample preparation duplicates and routine precision monitoring.

Coefficient of Variation (CV%)

CV% is a standardised measure of relative variability. For duplicate measurements it expresses the standard deviation of the pair as a percentage of the mean, so precision can be compared across different concentration ranges:

Mean = (2.50 + 2.40) / 2 = 2.45    CV% = 0.10 / (1.414 × 2.45) × 100 = 2.89

It is used in laboratory precision studies, duplicate sample monitoring, method validation and inter-laboratory comparisons.

Half Absolute Relative Difference (HARD%)

HARD% scales the duplicate difference by the sum of the two results:

HARD% = 0.10 / 4.90 × 100 = 2.04

Because a + b is twice the pair mean, HARD% is exactly half of the absolute MPRD%, so its values are half as large: a HARD% limit of 10% corresponds to an MPRD% limit of ±20%.

Mean Pair Relative Difference (MPRD%)

MPRD% is a symmetric duplicate precision statistic based on the average of both results. Because neither value is treated as the reference measurement, it is often preferred for routine duplicate precision assessment:

MPRD% = (2.50 − 2.40) / 2.45 × 100 = +4.08

QC Analytical Results keeps the sign: positive when Sample 1 (a) is higher, negative when Sample 2 (b) is. A run of one sign on RD v Sequence shows a bias between Sample 1 and Sample 2; the Overview uses the absolute value. (MPRD% without its sign is sometimes called bl%; QC Analytical Results does not offer it separately.)

Hyslop Relative Difference (RDHYSLOP)

From Hyslop, N.P. and White, W.H. (2009), Estimating Precision Using Duplicate Measurements, Journal of the Air & Waste Management Association, 59(9), 1032–1039.

RDHYSLOP is the difference between the pair, divided by √2 and by the pair mean, as a percentage, with its sign kept. Dividing by √2 turns the difference of two results into the standard deviation of one, so for a single pair it is the CV% with a sign:

RDHYSLOP = 0.10 / (1.4142 × 2.45) × 100 = +2.89

Values near zero indicate strong duplicate agreement. The sign shows which result was higher: positive when Sample 1 (a) is higher, negative when Sample 2 (b) is. Hyslop and White estimate the precision of a whole set of pairs as the root mean square of these values; QC Analytical Results charts each pair’s value.

General guide

Absolute value Assessment
< 5% Excellent agreement
5–10% Acceptable agreement
> 10% Investigation may be required

These bands are a general guide only: what is acceptable depends on the check stage, the element and its concentration.

References

  • Hyslop, N.P. and White, W.H. (2009). Estimating precision using duplicate measurements. Journal of the Air & Waste Management Association, 59(9), 1032–1039.
  • Stanley, C.R. and Lawie, D. (2007). Average relative error in geochemical determinations: clarification, calculation, and a plea for consistency. Exploration and Mining Geology, 16(3–4), 267–275.
  • Abzalov, M. (2008). Quality control of assay data: a review of procedures for measuring and monitoring precision and accuracy. Exploration and Mining Geology, 17(3–4), 131–144.